Sources and simplifications

Every reference cited on this site, and every place a figure idealizes the real system.

References

  1. Amtrol (Worthington Industries) (2019). Well-X-Trol: Next Generation Well Tanks Featuring Antimicrobial Protection (specifications and ESP quick sizing table), form MC 7025 (04/19). Amtrol, West Warwick, RI. manufacturer data sheet Drawdown at 30/50, 40/60 and 50/70 psig for WX-101 to WX-350 (e.g. WX-202, 20 gal: 6.2 / 5.4 / 4.7 gal); factory precharge 38 psig; sizing table built on 1-minute run time for pumps up to 3/4 hp and 2 minutes above; note that drawdown depends on temperature and pressure. (How the tank works)
  2. Amtrol (2019). Well-X-Trol Installation and Operation Instructions, 9015-868 MC10185 (06/19). Amtrol, West Warwick, RI. manufacturer manual How a well tank works (air above the diaphragm compressed as water enters); set precharge 2 psig below cut-in (38 psig for 40/60); adjust only with the tank drained and the system off, at ambient temperature; explosion hazard warnings; only licensed professionals should check or re-charge; licensed professional inspection yearly. (How the tank works)
  3. Flowers, P., Theopold, K., Langley, R. & Robinson, W. R. (2019). Chemistry 2e, §9.2 Relating Pressure, Volume, Amount, and Temperature: The Ideal Gas Law. OpenStax, Rice University. textbook Boyle's law: at constant temperature and amount, the volume of a gas is inversely proportional to its pressure (PV = constant); ideal-gas assumptions. (How the tank works)
  4. Thompson, A. & Taylor, B. N. (2008). Guide for the Use of the International System of Units (SI), NIST SP 811, Appendix B.8 Factors for units listed alphabetically. National Institute of Standards and Technology. standard Standard atmosphere = 1.01325 × 10⁵ Pa; 1 psi = 6.894757 × 10³ Pa; so 1 atm = 14.696 psi. (How the tank works)
  5. Pentair Residential Filtration (2014). WellMate In-Line Pressure Tanks data sheet, WM01 Rev D. Pentair, Milwaukee, WI. manufacturer data sheet Drawdown volume multiplier chart 'based on Boyle's Law' (e.g. 20/40: .35; 40/60: .25); tank size = pump gpm × minimum run time ÷ multiplier; recommends at least 1 minute run time. (How the tank works)
  6. Xylem / Goulds Water Technology (2025). HYDRO-PRO Tanks: Cross Reference and Sizing Guide, CRSGTANK R2. Xylem Inc., Seneca Falls, NY. manufacturer data sheet Sizing for one-minute ('adequate') and two-minute ('recommended') pump run times at 20/40, 30/50 and 40/60; 'Precharge at 2 lbs. below cut-in setting of pressure switch.' Revision R2, dated 3/2025 in the footer. (How the tank works)
  7. Friedman, D. (InspectApedia) (2024). Diagnose and Repair Air Discharge at Faucets and Fixtures. InspectApedia. reference website Causes of air at the taps on a private well: falling well water level, a leak in the drop pipe, a failed air-volume control, a burst bladder (the tank then waterlogs and the pump short-cycles), a check valve that lets water drain back. Year approximate (page undated; read 2026-11-10). (How the tank works)
  8. Franklin Electric (2026). AIM Manual: 60 Hz Submersible Systems, Application · Installation · Maintenance, 2026 edition. Franklin Electric Co., Fort Wayne, IN (copy hosted by the Nebraska Department of Water, Energy, and Environment). manufacturer manual p. 4 Frequency of Starts: excessive cycling damages control components, splines, bearings and windings; run motors at least one minute; maximum starts per 24 h (300 for encapsulated motors up to 0.75 hp); p. 7 check valves hold pressure when the pump stops; VFD section: small tank, 10–20% of pump output per minute, max 200 starts/24 h. (How the tank works)
  9. Grundfos (2000). SQ/SQE Stainless Steel Submersible Pumps (product brochure). Grundfos (distributor copy). manufacturer brochure SQE motor speed variable between 65% and 100%; the CU 301 controller holds a constant pressure from a pressure sensor; soft start with a 2-second ramp. Year approximate (c. 2000). (How the tank works)
  10. Friedman, D. (InspectApedia) (2024). Water pump won't start, won't stop, or short cycles (diagnostic table 1 of 3). InspectApedia. reference website Pump will not shut off: water running, damaged pump cannot reach cut-off, cut-off set too high, clogged pressure-switch sensor port; a pump that does not turn off creates a dangerous over-pressure condition. Short cycling: waterlogged tank most common, too little precharge; very rapid cycling can be a clogged water filter or blockage on the pump's outlet side. Pump starts with no use: slow leak (running toilet), leaky check or foot valve. Year approximate (undated; newest reader note 2024; read 2026-11-10). (Why Your Well Pump Keeps Cycling)
  11. Friedman, D. (InspectApedia) (2024). Diagnose and Repair Poor Water Pressure / Lost Well Water Pressure. InspectApedia. reference website Poor pressure from pump, tank or control-switch problems; low well yield; rust-clogged steel supply piping; small-diameter piping limits flow; a clogged water filter reduces pressure. Year approximate (undated; read 2026-11-10). (Why Your Well Pump Keeps Cycling)
  12. Xylem / Goulds Water Technology (2025). 4" Submersible Pumps Quick Guide, IM453 Rev 2. Xylem Inc.. manufacturer manual Check valve for every 200 ft of vertical pipe; some installers add one on the discharge even with a built-in valve; with a pitless adapter the top check valve should be below the pitless, not at the tank; with well seals or well pits it is allowable to locate the top check valve near the tank. Footer IM453_Rev 2_2025-07. (Why Your Well Pump Keeps Cycling)
  13. Wisconsin Department of Natural Resources (2021). You and Your Well (PUB-DG-002). Wisconsin DNR, Drinking and Groundwater program. state guidance In Wisconsin only persons with a current pump installer license may install and replace pumps, pitless adapters, piping and pressure tanks. Year approximate (no date printed). (Why Your Well Pump Keeps Cycling)
  14. Square D by Schneider Electric (2011). Pumptrol Water Pump and Air Compressor Pressure Switches (catalog pages, Class 9013 Type FSG). Schneider Electric. manufacturer catalog Standard settings 20/40, 30/50, 40/60 psig; FSG2 cut-in range 20–65 psig, adjustable differential about 15–30 psig; 'Differential: the difference between cut-in and cut-out pressure'; low-pressure cut-off option opens at about 10 psig below cut-in to stop the pump if it runs dry or a line breaks. (Why Your Well Pump Keeps Cycling)
  15. Schneider Electric (2007). How do you adjust the settings on a 9013FSG switch? (FAQ FA121330). Schneider Electric. manufacturer FAQ The large range nut sets cut-in (and moves cut-out with it); the small differential nut sets cut-out only. Published 2007, modified 2026. (Why Your Well Pump Keeps Cycling)

Simplifications