Sources and simplifications
Every reference cited on this site, and every place a figure idealizes the real system.
References§
- (2012). A/C-Heat Pump System Troubleshooting Guide for the Testo 550. TruTech Tools, Akron, OH. trade training Tables of suction pressure, liquid pressure, superheat and subcooling direction for common faults on fixed-orifice and TXV systems (overcharge, undercharge, liquid restriction, low evaporator airflow, dirty condenser, low ambient, inefficient compressor, non-condensables, TXV bulb faults); typical TXV subcooling 8–12 °F, evaporator superheat 6–12 °F; fixed-orifice target superheat 5–40 °F depending on indoor wet bulb and outdoor dry bulb; DTD 35 °F, condenser +20 to +30 °F; check airflow first; measure both superheat and subcooling. (Superheat and subcooling)
- (2003). Pseudo-Pure Fluid Equations of State for the Refrigerant Blends R-410A, R-404A, R-507A, and R-407C. International Journal of Thermophysics 24(4): 991–1006 (copy hosted by NIST). journal article R-410A = 50% R-32 / 50% R-125 by mass; Helmholtz-energy equation fitted to the full mixture model (densities within 0.1% except near the critical point; heat capacities 0.1% average, 0.5% max); dew and bubble pressures from ancillary Eq. 13 (Table VI), within 0.02–0.05% of the mixture model; valid 200–450 K; Table V check values (300 K: bubble 1.7404 MPa, dew 1.7351 MPa); dew and bubble curves of R-410A nearly coincident. (Superheat and subcooling)
- (2021). “The Pressures Look Good.” How Do You Know?. HVAC School. trade training Evaporator design temperature difference (DTD) about 35 °F ± 3 below return air; condensing temperature over ambient (CTOA) 30 °F (6–9 SEER), 25 °F (10–12), 20 °F (13–16), 15 °F (17+); worked example for R-410A: 74 °F return, 88 °F outdoor → 39 °F evaporating (116.1 psig) and 108 °F condensing (356.5 psig). (Superheat and subcooling)
- (2022). Introduction to Engineering Thermodynamics, §6.3 Refrigerator and heat pump; §6.5 Carnot cycles. BCcampus / Engineering LibreTexts (CC BY-NC-SA 4.0). textbook The four devices of the vapour-compression cycle (evaporator, compressor, condenser, expansion valve); COP_R = Q_L/W, COP_HP = Q_H/W, COP_HP = COP_R + 1; adiabatic expansion valve with h4 = h3; reversible (Carnot) heat pump COP = T_H/(T_H − T_L), the highest possible between the two temperatures. (Superheat and subcooling)
- (2015). 25HBB5 Base Series Heat Pump with Puron Refrigerant: wiring diagrams and charging label. Carrier Corporation. manufacturer manual Required subcooling is given on the unit rating plate, with a ±3 °F tolerance; reversing valve solenoid and defrost control in the ladder diagram; relieve pressure and recover all refrigerant before system repair or final disposal. (Superheat and subcooling)
- (2020). EPA’s Refrigerant Management Requirements: What Technicians Need to Know (Section 608 fact sheet). U.S. EPA. government guidance Section 608 prohibits knowingly releasing refrigerant during maintenance, service, repair or disposal; requirements cover HCFCs and non-exempt substitutes such as HFCs and HFOs; only certified technicians can use non-exempt refrigerants to service AC and refrigeration equipment; refrigerant sales restricted to certified technicians; technicians must pass an approved certification exam. (Superheat and subcooling)
- (2008). Guide for the Use of the International System of Units (SI), NIST SP 811, Appendix B.8 Factors for units listed alphabetically. National Institute of Standards and Technology. standard Standard atmosphere = 1.01325 × 10⁵ Pa; 1 psi = 6.894757 × 10³ Pa (so 1 atm = 14.696 psi); T/K = (t/°F + 459.67)/1.8; 1 Btu_IT/lb = 2326 J/kg. (Superheat and subcooling)
- (1997). An International Standard Equation of State for Difluoromethane (R-32) for Temperatures from the Triple Point at 136.34 K to 435 K and Pressures up to 70 MPa. Journal of Physical and Chemical Reference Data 26(6): 1273–1328. doi:10.1063/1.556002. journal article Read via the NIST Chemistry WebBook fluid page for R-32, which uses this equation and states its estimated uncertainties: 0.05% for density, 0.02% for vapor pressure, 0.5–1% for liquid heat capacity and speed of sound. (About)
- (2014). Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp. Industrial & Engineering Chemistry Research 53(6): 2498–2508. doi:10.1021/ie4033999. software CoolProp (MIT licence), version 8.0.0, implements the Lemmon (2003) R-410A and Tillner-Roth & Yokozeki (1997) R-32 equations used to build this site's property tables. (About)
- (2016). University Physics Volume 2, §4.3 Refrigerators and Heat Pumps. OpenStax, Rice University. textbook Coefficients of performance K_R = Q_c/W and K_P = Q_h/W; the coolant vaporizes in the evaporator taking heat from the cold side and exhausts heat to the outside in the condenser. (How does a heat pump or air conditioner move heat?)
- (2025). What Is a Reversing Valve in a Heat Pump?. Carrier Corporation. manufacturer guide The reversing valve switches the system between heating and cooling by changing the direction of refrigerant flow; energized position depends on the system design; reversing valve issues involve refrigerant handling, which requires professional certification. (How does a heat pump or air conditioner move heat?)
- (2018). Charging a Heat Pump in Heat Mode. HVAC School. trade training Heat mode rules of thumb: suction saturation 20–25 °F below outdoor ambient; condensing temperature 30–40 °F above indoor dry bulb; manufacturer charts are the better reference. (How does a heat pump or air conditioner move heat?)
- (2021). Cost-Optimized Cold Climate Heat Pump Development and Field Test, ORNL/TM-2021/2044. Oak Ridge National Laboratory, for the U.S. Department of Energy. government report §1: heating capacity of a single-speed ASHP decreases with ambient temperature, typically to 20–40% of the 47 °F rating at −13 °F; low suction pressure and high pressure ratio cause high discharge temperatures; heating COP degrades at low ambient because of the large source–sink temperature difference; prototype CCHP: COP 4.24 at 47 °F, 2.9 at 17 °F, 1.9 at 76% of nominal capacity at −13 °F. (How does a heat pump or air conditioner move heat?)
- (2025). Thermophysical Properties of Fluid Systems: Difluoromethane (R-32), saturation properties (NIST Chemistry WebBook, SRD 69). National Institute of Standards and Technology. government data R-32 saturation table (e.g. 0 °C: 0.8131 MPa, h_L 200.00, h_V 515.30 kJ/kg; 30 °C: 1.9275 MPa); IIR reference state (h = 200 kJ/kg, s = 1 kJ/kg·K for saturated liquid at 0 °C); critical point 78.105 °C, 5.782 MPa; equation of state Tillner-Roth & Yokozeki (1997). (How does a heat pump or air conditioner move heat?)
- (2023). Basic Engineering Science: A Systems, Accounting, and Modeling Approach, §7.9 Thermodynamic Cycles. Engineering LibreTexts. textbook Most refrigeration systems, whether cooling the air in a house, the food in a refrigerator or the freezer display cases in a grocery store, are mechanical vapour-compression cycles; a window air conditioner is modelled as one. (How does a heat pump or air conditioner move heat?)
- (2010). Operations & Maintenance Best Practices Guide, Release 3.0, §9.4 Chillers. U.S. Department of Energy, Federal Energy Management Program. government guidance §9.4.1: a chiller is a refrigeration system that cools water and, like an air conditioner, uses either a vapor-compression or an absorption cycle; §9.4.2.1: the mechanical compression cycle has four basic components (evaporator, compressor, condenser, expansion valve); diagnostic tools listed for 'packaged cooling systems including roof-top units' alongside split systems. (How does a heat pump or air conditioner move heat?)
- (2024). 2025 A2L Regulatory Guide (RHM5848A). Rheem Manufacturing Company. manufacturer guide EPA Technology Transitions Rule (AIM Act): 700 GWP limit for new residential air conditioners and heat pumps from 2025, which rules out R-410A (GWP 2,088); R-454B and R-32 are the A2L alternatives; existing equipment need not be replaced. (How does a heat pump or air conditioner move heat?)
Simplifications§
- The coil figures unroll each coil into one tube in air of one temperature, and draw the warming and cooling after the phase change as a simple exponential approach.
- The chart is an ideal cycle drawn with real refrigerant properties: no pressure drops, fixed superheat and subcooling, a fixed compressor efficiency, and coil temperatures from typical rules of thumb.